  1.  
  2.                                Release Notes
  3.                                =============
  4.  
  5.                                     for
  6.  
  7.                             PC-Duo Version 1.02
  8.                             ===================
  9.  
  10.  
  11.               Copyright (c) 1994 PCI, Vector Networks Limited
  12.                             All Rights Reserved.
  13.  
  14.  
  15. Author        : D. Briggs.
  16.  
  17. Revision Date : 19th September 1994
  18.  
  19.  
  20. This document  contains the release notes  accompanying version 1.02 of the
  21. PC-Duo PC-PC Remote Control package.
  22.  
  23. This software is supplied under a licence and may only be used or copied in
  24. accordance with the terms of that licence.  This software or copies thereof
  25. must not be made available to unauthorised personnel.
  26.  
  27. No  title  to  this  software  nor  ownership  of  this  software is hereby
  28. transferred.
  29.  
  30. Evaluation  copies are  supplied for  the purpose  of evaluation  only  and
  31. must  not  be  resold  or  passed  to  any  third party without the express
  32. permission of Vector Networks Limited.
  33.  
  34. Please note that serial number  files (SLAVE.SER) for versions earlier than
  35. 1.02 will not work  with this release.  Please contact your  supplier for a
  36. new authorisation key if necessary.
  37.  
  38. Package Enhancements over the Previous Release.
  39. ===============================================
  40.  
  41. This release implements Windows to Windows SHOW.
  42.  
  43. Reliability  of  remote  communications  has  been  improved substantially,
  44. particularly on configurations prone to errors or "dropped" characters.
  45.  
  46. The Windows Control now allows  modem configurations to be edited.  Several
  47. new modem configurations have been added.
  48.  
  49. The Slaves can log  events to a (shared) log file.  This is activated using
  50. the /y<filename> command line option.
  51.  
  52. The Control programs can  operate from a shared  (read-only)  file service,
  53. provided that  copies of the configuration files (CONTROL.CFG, CONTROL.DIR,
  54. and CONTROL.MDM) are copied  to a private directory.  This directory should
  55. be the current  default directory  when a Control program is activated.  It
  56. will search  the current  directory  for  these files  before it checks the
  57. PCDUO installation directory.  Write access to the directory is required in
  58. order to save changes to the configuration or dialling directory.
  59.  
  60. The size of the  bitmap cache used by  Windows Slave  and Control  programs
  61. can be controlled using the /H<size> command line option.  Values specified
  62. should be in the range 128 to 1024 (kbytes). Default values are 256 for the
  63. Slave, and 1024 for the Control.
  64.  
  65. The  Dialling Directory  can now  hold numbers  with up to 31 digits.  This
  66. allows Mercury access codes to be used with international numbers.
  67.  
  68. Problems Corrected in this Release.
  69. ===================================
  70.  
  71. ATI MACH 32 and Compaq Qvision adapters are now supported.  Note that a bug
  72. in the ATI driver transposes light and dark grey on a 256 colour Slave when
  73. it is viewed from a 16 colour Control.
  74.  
  75. The Control's Slave look-up timeout value has been increased from 8 seconds
  76. to 14.  This should  help in situations where  the value set in the Slave's
  77. Windows SYSTEM.INI [386Enh] TimerCriticalSection line is 10000. This is the
  78. default value for PATHWORKS 4.x,  and it can cause problems  when a Control
  79. is searching for available Slaves and also when it is attempting to connect
  80. to a Slave.
  81.  
  82. Alternatively, if you experience problems when connecting to Slaves running
  83. TSRs  such as Dr Solomon's VirusGuard,  or with terminal emulators  such as
  84. Reflection 2 or 4 for Windows,  try reducing the TimerCriticalSection value
  85. to 1000.
  86.  
  87. PC-Duo is now compatible with Bitstream Facelift 2.0 and Adobe Type Manager
  88. (ATM).  Note that the use of  Adobe Type Manager is not recommended,  as it
  89. displays text as bitmaps.  This is inefficient,  especially over dial-up or
  90. serial connections. ATM text is always displayed in black on the Control.
  91.  
  92. Bitmap  checksumming  has  been  improved.  This  should  result  in  fewer
  93. "mistakes" when complex bitmaps or DOS text screens are being displayed.
  94.  
  95. Keystrokes are  now passed into a  Windows DOS box  on the Slave,  when the
  96. Control is  running in  Control mode.  Note that Control mode  has not been
  97. implemented under Windows. It behaves the same as Share mode.
  98.  
  99. The Windows Slave now reports an error if the current display resolution is
  100. set for more than 256 colours.
  101.  
  102. Known Problems in this Release.
  103. ===============================
  104.  
  105. Most  popular display  adapters are  supported.  However,  not all  Windows
  106. display  accelerators are  supported in  this release.  Problems have  been
  107. reported with Olivetti EVD and Number Nine 9GXE display adapters.
  108.  
  109. If you have a problem with a Windows Accelerator,  and can't resolve  it by
  110. reducing  the display  resolution  (e.g. to  Super VGA 800*600*16 colours),
  111. please contact your supplier for further assistance.
  112.  
  113. When dragging objects in PowerPoint or MS-Draw on  Windows Slaves using the
  114. S3  display  accelerator,  the  dotted  object  outline  is  not  displayed
  115. correctly on a connected Control.  The object is re-drawn correctly when it
  116. is "dropped".
  117.  
  118. When large bitmap images  are moved around the Windows Slave display,  such
  119. as when outline dragging in Solitaire  is disabled,  the Windows Slave  can
  120. have problems  keeping  up with the  moving image.  This is more likely  to
  121. occur on  slow PCs,  and can occasionally  result in  "dropped cards".  The
  122. "damaged" area can be repaired by moving another object over it.
  123.  
  124. A  DOS Control  running in a Windows DOS box cannot make remote connections
  125. via a loaded Remote program.
  126.  
  127. Some ICL PCs  exhibit a "Sticky Control" key.  The Slave thinks the Control
  128. key is down,  when it isn't.  This  results in  incorrect characters  being
  129. received by the application running on the Slave. It can usually be cleared
  130. by  tapping  the Control  key on  the Control.  If this  doesn't help,  try
  131. setting the Control to BIOS Keyboard (instead of Low Level Keyboard).
  132.  
  133. A problem has been reported with Borland dBASE IV version 1.1 for DOS. This
  134. reports  an EMM386  Exception Error 3  when dBASE is started.  This problem
  135. does not occur with dBASE IV version 2.0 for DOS.
  136.  
  137. Starting the  Windows Slave  from the  StartUp Group instead of the WIN.INI
  138. [windows]  run=  line  can  occasionally  produce  problems.  This  is  not
  139. recommended,  and the Setup program will always make  the change to WIN.INI
  140. if Windows Slave support is selected.
  141.  
  142. Connecting to Slaves running  DOS boxes under  Windows may be unreliable on
  143. some machines.  The chance of a problem occurring can  be reduced by making
  144. the DOS box exclusive in the appropriate PIF file.
  145.  
  146. Documentation Notes.
  147. ====================
  148.  
  149. Many packages use  their own screen fonts  (e.g. Reflection 2 for Windows).
  150. When a program  like this is running on a Slave, a connected Control cannot
  151. display the  Slave's screen correctly  if it doesn't  recognise the Slave's
  152. fonts.  In order to correct  this  situation,  it is necessary for the font
  153. file(s)  to be copied  from  the Slave  into the  Control's  WINDOWS\SYSTEM
  154. directory. Once there, they can be installed using Windows Control Panel.
  155.  
  156. Diagnostic Utilities
  157. ====================
  158.  
  159. The following LANlink diagnostic utilities have been provided with PC-Duo :
  160.  
  161. NBSTATUS.EXE    NetBIOS Adapter and Session Status Display
  162. NETBTEST.EXE    NetBIOS Test Program
  163.  
  164. These programs  can  be  found  in  the  \LANLINK  directory on  the PC-Duo
  165. Demonstration  Disk.   They  are  not  installed  by  the  DOS  or  Windows
  166. installation procedures.
  167.  
  168. Use /? or /h options for usage instructions.
  169.  
  170. Vector Networks' LANlink is a suite of network interconnect packages.
  171.  
  172. Automated Installation with LANutil
  173. ===================================
  174.  
  175. LANutil  Automated  Installation  Scripts  are  provided  in  the  \LANUTIL
  176. directory on the  PC-Duo Demonstration Disk.  They can be used with  Vector
  177. Networks'  LANutil for PATHWORKS  package to install PC-Duo  automatically.
  178. The script files are VMS files, and are provided on the disk as plain ASCII
  179. text files,  although they have been renamed  to suit the DOS 8.3 character
  180. filename limits.
  181.  
  182. DOS Files    VMS Filename           Purpose
  183.  
  184. PCDAUTO.TPU  PCDUO_AUTOEXEC.TPU     Edits AUTOEXEC.BAT to call STARTSLV.BAT
  185. PCDCUS.CMD   PCDUO_CUSTOM.COM       Customises installation on target PC
  186. PCDINS.CMD   PCDUO_INSTALL.COM      Controls network-wide installation
  187. PCDPROG.TPU  PCDUO_PROGMAN_INI.TPU  Edits PROGMAN.INI to add PCDUO.GRP
  188. PRDPROT.TPU  PCDUO_PROTOCOL_INI.TPU Edits PROTOCOL.INI [NetBEUI] section
  189. PCDSYS.TPU   PCDUO_SYSTEM_INI.TPU   Edits SYSTEM.INI to load PC-Duo drivers
  190. PCDTPL.TPU   PCDUO_TEMPLATE.TPU     Edits PATHWORKS V5 for DOS Template(s)
  191. PCDWIN.TPU   PCDUO_WIN_INI.TPU      Edits WIN.INI to load Windows Slave
  192.  
  193. These files  should be copied onto  the LANutil  host  (in ASCII)  mode and
  194. renamed according to the list above. They require LANutil V2.0 or later for
  195. correct operation.